Problem solving
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)
70
E7 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
E8 Error during ionization test. Electronic control unit
internal error.
Replace electronic control unit.
1)
E9 Thermal fuse [13] broken. Replace thermal fuse.
1)
EA Ignition failure. Check gas inlet pressure ( section 4.13).
1)
Perform gas and air tuning ( section 8.12).
1)
EB Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
EC Flame lost during operation. Check gas inlet pressure ( section 4.13).
1)
Perform gas and air tuning ( section 8.12).
1)
EE Gas valve modulation solenoid [7] disconnected. Check gas valve wire connection.
1)
If the problem persists:
Replace the gas valve and/or wire connections and/
or electronic control unit. For gas valve replacement
perform gas and air tuning ( section 8.12).
1)
EF Wrong gas connected (LP instead of NG) for
current appliance configuration.
Check gas type ( section 6.8).
1)
F2 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F3 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If appliance’s configuration is required:
See section 6.6 to configure appliance (region,
power, type and gas type) and perform an automatic
combustion adjustment according to the
section 8.12.
1)
If the problem persists:
Replace electronic control unit.
1)
F7 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F8 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F9 Gas valve driver internal fault. Check gas valve wire connections.
1)
If the problem persists:
Replace the wire connections and/or electronic
control unit.
1)
Display Description Solution

Table of Contents