Installation instructions
3.6.7 Exhaust vent configuration examples
Fig. 24 Horizontal side wall venting installation
Fig. 25 Vertical venting installation - Masonry
Chimney
Fig. 26 Vertical venting installation
NOTE: If appliance uses room air, do not place any
other combustion appliance in the same space, to avoid
depressurizing of the building and winter freeze-up. Use
room sealed operation instead.
FIRESTOP SUPPORT
HANGER STRAPS
ELBOW
TO DRAIN - DISPOSE
OF CONDENSATE
ACCORDING TO
LOCAL CODES
APPLIANCE
RAIN CAP
STORM COLLAR
FLASHING
4" MIN.
AIR SPACE
6720607915-14.6JS
HORIZONTAL RUN
1/4" RISE/FT
FROM HEATER
CONDENSATE
DRAIN