30" Appliances
Dimensions for 30" Wall-Mounted Units
293/4"
2713/16"
(706ram)
281/2"
'_- (724mm)
24" /------_
(610ram)
(718mm)
i
27"
(686mm)
237/8" (606ram)
!, 22"(559mm)
rain. 43/4"(121mm)
max. 313/8"
l_
Single Oven 30"
It is good practice, when oven is
installed at the end of a cabinet run,
adjacent to a perpendicular wall or
cabinet door, to allow at least 1/4"
space between the side of the oven
and the wall/door.
For oven support, install 2x4's
extending front to back flush with the
bottom and the side of the opening.
The supporting base must be well
secured to the floor/cabinet and level.
Note: The conduit box must be
installed either above or below the
unit. If the conduit box is installed
below the unit, a 2" diameter hole or
space is required between the back
wall and the right rear of the 2x4
supports.
The cabinet base must be flat and
capable of supporting a weight of at
least 190 Ibs (86 kg).
293/4"
k (755mm) 2713/16"
(706ram)
513/4"
(1314mm)
24"
493/4"
(1264mm)
2
237/8" (606ram)
Lj 22" (559mm)
511/8"
(1299mm)
93/4"
(248mm)
s__
Double Oven 30"
It is good practice, when oven is
installed at the end of a cabinet run,
adjacent to a perpendicular wall or
cabinet door, to allow at least 1/4"
space between the side of the oven
and the wall/door.
For oven support, install 2x4's
extending front to back flush with the
bottom and the side of the opening.
The supporting base must be well
secured to the floor/cabinet and level.
Note: The conduit box must be located
above the unit to facilitate connecting
and servicing.
The cabinet base must be fiat and
capable of supporting a weight of at
least 330 Ibs (150 kg).