General nozzle table
Nominal operating pressure
The nominal operating pressure of your appliance is:
â– for natural gas 1.0 kPa.
â– for liquefied gas 2.75 kPa.
Your appliance must be operated at these pressure values. All
information on the rating plate refers to these pressure values.
The manufacturer does not accept any liability for operability,
power of the appliance or for other risks if the appliance is
operated at pressure values other than those values specified
for the appliance.
Positioning and levelling
Fitting tilt protection
A fixing kit accompanies the appliance for fastening the
appliance to the wall. This kit contains fixing accessories and
installation instructions. Refer to these instructions during
installation.
Note: The installation instructions are intended for several
appliances. You can find the designation of the appliance which
is relevant for you on the rating plate.
Positioning the appliance
When installing the appliance, make sure that there is enough
space in the final installation location to pull the appliance
forwards for cleaning and maintenance work.
The ground underneath must be hard and firm. The wall
immediately behind the appliance must be made from non-
flammable material, e.g. tiles.
If you need to move the appliance in order to position it, make
sure that the adjustable feet are fully screwed in.
Levelling the appliance
Level the appliance once all other work has been completed.
To do this, turn the adjustable feet.
Type of gas kPa Nozzle number Type of burner Power
(MJ/h)
Power
min. (MJ/h)
Natural gas 1.0 155 High output burner 12 2.7
120 Standard burner 7.5 1.5
90 Economy burner 3.9 1.5
185 Wok burner 15.8 5.4
Liquefied gas 2.75 88 High output burner 10.8 2.7
68 Standard burner 6.3 1.5
54 Economy burner 3.9 1.5
105 Wok burner 15 5.4