Fault Possible cause Remedial action
Bottom
of the refrigerator
compartment is wet.
The condensation
channel or drainage
hole are blocked.
Clean the condensation channel
and the drainage hole. See chapter
Cleaning the appliance. Fig. 3
The temperature in
the refrigerator
compartment is too
cold.
Temperature has been
set too low.
Increase the temperature.
The refrigerating unit
is switching on more
frequently and for
longer.
Appliance opened
frequently.
Do not open the appliance
unnecessarily.
The ventilation
openings have been
covered.
Remove obstacles.
Appliance is not
cooling, temperature
display and light
are lit.
Showroom mode is
switched on.
Hold down temperature selection
button fig. 2/3 for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether
your appliance is cooling.