Technical Data
Assembly
Inserting/Replacing the Battery
Use only alkali-manganese batteries.
To open the battery lid 11, press the latch 10 in the direction of the
arrow and remove the battery lid. Insert the batteries provided. Pay
attention to the correct polarity of the batteries according to the rep-
resentation in the battery compartment.
Always replace all batteries at the same time. Only use batteries
from one brand and with the identical capacity.
f Remove the batteries from the measuring tool when not
using it for extended periods. When storing for extended
periods, the batteries can corrode and discharge themselves.
Line laser PLL 5
Article number 3 603 K15 000
Working range to approx.* 5 m
Levelling accuracy** ± 1mm/m
Operating temperature +5 °C...+40 °C
Storage temperature –20°C...+70°C
Relative air humidity, max. 90 %
Laser class 2
Laser type 635 nm, <2 mW
C
6
9.33
Batteries 2 x 1.5 V DC LR03 (AAA)
Weight according to
EPTA-Procedure 01/2003
0.12 kg
Dimensions 142 x 27 x 30 mm
* when using the wall holder 1; under unfavourable conditions such as
intense sun irradiation, the working range is smaller
** when the measuring tool is positioned correctly (see “Positioning the
Measuring Tool”, page 20)
Please observe the article number on the type plate of your measuring tool.