Do you have a question about the Bosch Rexroth VCH 08.1 and is the answer not in the manual?
Display Size | 8.4 inches |
---|---|
Display Type | TFT |
Touchscreen | Yes, resistive |
Processor | Intel Atom |
Interfaces | 2x USB |
Describes the Hand-held Terminal IndraControl VCH 08.1 as a portable operator and visualization device.
Explains how the terminal connects to the control via a connection module.
Outlines the steps for mounting and connecting the terminal for operation.
Details the PC-based operating/visualization device and its typical applications.
Defines inappropriate use and conditions under which the terminal must not be used.
Lists prerequisites for safe operation, including following instructions and using qualified personnel.
Lists potential hazards such as high voltage, dangerous movements, and burns.
Addresses safety measures for components operating above 50 volts.
Explains the use of PELV for connecting devices with basic insulation to extra-low voltage.
Discusses hazards from faulty control of connected motors and how to avoid accidents.
Warns about dangers from magnetic/electromagnetic fields for people with implants.
Advises caution regarding hot surfaces of components and risk of burns.
Provides safety guidelines for handling and mounting equipment to prevent injury.
Warns about risks associated with pressurized lines and systems.
Provides detailed technical specifications for the IndraControl VCH 08.1.
Lists technical specifications for the keyboard, housing, and display components.
Details technical data for the stop and emergency stop buttons.
Provides technical data, including category and panic, for the enabling button.
Discusses additional measures for safety and the role of the terminal as a safety component.
Discusses shielding and filtering as EMC measures for reliable device operation.
Describes the safety concept, including the 2-circuit enabling button.
Compares red-yellow emergency stop and gray stop buttons and their functionality.
Describes the two enabling buttons, their parallel operation, and 3-stage design.
Addresses impermissible fixing of the enabling switch and recommended measures.
Shows pin assignments for the VAC 30.2/31.1 connection module.
Details the DC 24 V voltage supply and its technical data.
Provides pin assignment for the STOP pushbutton.
Provides pin assignment for the emergency stop button.
Provides pin assignment for the enabling button.
Details connection examples for enabling buttons to meet safety categories.
Explains how to start system settings or the customer application.
Explains how to start the service dialog to configure network and hardware.
Lists settings available in the Config Tool, like brightness and calibration.
Explains how to start Rexroth Settings for network and application parameters.
Provides bit assignment for function blocks, VEH, VCH, and notes.
Explains the Config Tool for calibration and function control.