EasyManua.ls Logo

Bosch SGS4HTI33E - Page 40

Bosch SGS4HTI33E
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NL Troubleshooting
Malfunction Cause Troubleshooting
E:32-00 lights up alternately
or water supply indicator
lights up.
The strainers in the water
connection of the supply or
AquaStop hose are
clogged.
1. Turn off the device.
2. Remove the plug from the socket.
3. Turn off the tap.
4. Unscrew the water connection.
5. Remove the strainer from the inlet hose
6. Clean the strainer.
7. Place the strainer in the supply hose.
8. Screw on the water connection.
9. Check the water connection for
leaks.
10. Put the plug back in the
socket.
11. Turn on the device.
E:92-40 lights up alternately. Strainers are dirty or clogged.
Clean the sieves.
"Cleaning sieves", Page 37
E:61-03 lights up alternately.
The water is not pumped
out.
Drain hose is clogged or
kinked.
1. Route the drain hose without
kinks.
2. Remove the remains.
Siphon connection is still closed.
Check the connection to the
siphon and open it if necessary.
Drain pump cover is
loose.
Make the cover of the "drain
pump" Page 52 well fixed.
E:61-02 lights up alternately. Drain pump is blocked.
Clean the drain pump.
"Cleaning the drain
pump", page 52
Drain pump cover is
loose
Make the cover of the "drain
pump" Page 52 well fixed.
40

Table of Contents