107
IX.
IX.
Wiring Diagrams/Tech Sheet
Wiring Diagrams/Tech Sheet
Measuring SHU995x, SHV68 Circulation Pump Resistances @
Measuring SHU995x, SHV68 Circulation Pump Resistances @
Modules
Modules
~ 10 (with door closed)
SHU 995x/SHV 68
WH/RD
GY
HINT: To measure integrated model
resistances while door is open, use a
screwdriver to trip door latch closed.
CAUTION: Disconnect dishwasher
power before measuring circulation pump
motor resistance.
HINT: Can also
measure between VT
wire on terminal # 2
on e1 door switch and
GY wire on module
terminal I2.7-1.