EasyManuals Logo

Bosch SSB255 Technical Service Bulletin

Bosch SSB255
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Technical Service Bulletin:
Heat Exchanger: Refractory Replacement Procedure
Models: SSB255, SSB399, SSB512
Data subject to change without notice | Printed in the USA | BTC 438002102 B | 08.2019
Bosch Thermotechnology Corp.
WARNING:
The operations described here-below must be performed by
qualified personnel.
WARNING:
Before replacing the refractory, disconnect the equipment
from the power supply with the main ON/OFF switch and
close the manual gas shutoff valve.
CAUTION:
During every maintenance operation, always replace the
gaskets, especially the burner gaskets.
Replacement Procedure
Please follow the following steps for the refractory replacement:
1. Disconnect the two electrical connectors from the fan as shown in Fig.1
Figure 1
Electrical connectors
2. After closing the gas valve, disconnect the gas hose fi tting as shown in
Fig.2.
Figure 2
Gas hose fitting
3. Disassemble the fan by unscrewing the 4 nuts that lock the fl ange to the burner
head as shown in Fig. 3.
Figure 3
4. Pull the fan upwards as shown in Fig. 4.
Figure 4
Fig. 2
Fan Flange

Other manuals for Bosch SSB255

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SSB255 and is the answer not in the manual?

Bosch SSB255 Specifications

General IconGeneral
BrandBosch
ModelSSB255
CategoryBoiler
LanguageEnglish

Related product manuals