Page 1 from 45 6 720 887 546 “SM FP_ErP LPP/MPP Europe 2018/05 en”
LOW NOX INSTANTANEOUS
GAS WATER HEATER
ROOM SEALED FAN ASSISTED / PRESSURIZED
GAS WATER HEATER
FOR INDOOR INSTALLATION
TRAINING AND SERVICE INFORMATION FOR AFTER SALES
This document is restricted to exclusive use by the official service partners. Each
country should adapt the manual and its contents to the available range.

Questions and Answers

  • J
    jonathan52Sep 18, 2025
    What to do if my Bosch T2400S 8 ND 23 Water Heater indicates a gas valve wrong connection?
    • L
      ledwardsSep 18, 2025
      If a safety solenoid from the gas valve is disconnected, it indicates a gas valve wrong connection. The error is resolved by performing a manual reset.
  • D
    Darrell WallaceAug 25, 2025
    What to do if my Bosch Water Heater has exhaust blockage?
    • L
      Linda LeeAug 25, 2025
      If the fan speed and/or consumption detect a pressure above normal operating conditions on the exhaust, check configuration parameters like AS (altitude), F9 (flue exhaust code), AP (appliance power), etc.
  • J
    John WarnerAug 26, 2025
    What to do if my Bosch Water Heater shows temperature limiter or thermal fuse opened circuit?
    • G
      Gerald BruceAug 26, 2025
      This error occurs if the temperature limiter detects a temperature over 85ºC, or if the thermal fuse contact opens (192ºC) due to overheating and malfunction of the temperature limiter. The error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • A
    Anthony MurphyAug 27, 2025
    Why does my Bosch Water Heater display a water flow signal over specified maximum value?
    • S
      Sara CoxAug 27, 2025
      This error occurs when the water flow exceeds 22 l/min. The error is resolved when the water flow is below this value again.
  • S
    Sean WilkersonSep 22, 2025
    What causes an exhaust blockage error in my Bosch T2400S 8 ND 23?
    • J
      Joshua PerezSep 22, 2025
      If pressure above normal operating conditions is detected, it indicates an exhaust blockage. The error is resolved by performing a manual reset.
  • D
    Diana NavarroSep 23, 2025
    What does MCU RAM DC internal error mean for my Bosch T2400S 8 ND 23?
    • K
      Kenneth MorrisSep 23, 2025
      If voltage is too low (less than 70 V ac), it triggers an MCU RAM DC (micro controller) internal error. The error is resolved by performing a manual reset.
  • O
    ostokesSep 9, 2025
    What does it mean when my Bosch Water Heater displays MCU RAM DC (micro controller) internal error?
    • S
      sarahbushSep 10, 2025
      Check if the voltage is too low (less than 70V AC). This error is resolved by a manual reset. If the voltage is okay and the error persists, replace the control unit.
  • C
    Courtney ScottSep 12, 2025
    Why does my Bosch T2400S 8 ND 23 Water Heater show an error related to the temperature limiter or thermal fuse?
    • J
      jeffreywareSep 12, 2025
      If the temperature limiter detects a temperature over 85ºC, it causes the temperature limiter or thermal fuse to open the circuit. This error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • L
    logankatherineSep 3, 2025
    What to do if my Bosch T2400S 8 ND 23 Water Heater displays an internal checking failure?
    • A
      Adrienne WangSep 3, 2025
      This error is resolved by a manual reset. If the error persists, replace the control unit.
  • C
    Crystal BarberSep 1, 2025
    What to do if my Bosch T2400S 8 ND 23 remote controller removes the error code 5 times continuously within 15mins?
    • C
      Christian McclureSep 1, 2025
      This error is resolved by a manual reset.