Installation (only for approved contractors)
Tronic 5000 – 6721830067 (2021/06)
22
5.10.1 Configure the power level
▶Use jumpers J2 and J3 to configure the power level of the
appliance, according to the table below.
Table 6 Configuring the power
If the power of the appliance is changed,
Check which flow limiter should be used ( chapter 10).
5.10.2 Setting maximum temperature
Use Jumpers J4 and J5 to set the maximum temperature of
the appliance, according to the table below.
Table 7 Setting maximum temperature
5.10.3 Configuring and installing a Priority Relay
For the appliance to work with a priority electric circuit, a
special priority relay (BZ 45L21) is required. Other types of
priority relays, with the exception of electronic priority relays,
may not work correctly.
Fig. 39 Wiring diagram
Remove Jumper J1 to activate the Priority Relay mode in
the appliance's electronics system, see table below.
TR... 11/
13
TR... 15/
18/21
TR... 21/
24/27
Jumpers: J2 - J3
13 kW
(Factory
Settings)
21 kW
(Factory
Settings)
27 kW
(Factory
Settings)
11 kW
18 kW 24 kW
15 kW 21 kW
Max. Temperature Jumpers: J4 - J5
Maximum Temperature 60 °C
(Factory Settings)
Maximum Temperature 53 °C
(EN60335 - if the appliance
supplies water for showering)
Maximum Temperature 48 °C
Maximum Temperature 42 °C
Max. Temperature Jumpers: J4 - J5