EasyManua.ls Logo

Bosch Tronic 3000 C Pro US12 - Electrical Connections

Bosch Tronic 3000 C Pro US12
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 | Installation US
6 720 647 088 (2011/09)
4.4 Electrical connections
B Strip back the insulation on the power wires about 3/
8". Any insulation on the ground should be stripped
back about 3/4".
B Feed the cable through the cover bottom or backplate
entry grommets, as appropriate.
B Connect the cables to the terminal block and ground
stud (Fig. 3):
Fig. 3 Cable termination
B Make sure that all the terminal block screws are
tightened securely. Loose connections can cause
wires to neat up.
B Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut
should be tightened securely.
B Attach the front cover and tighten the retaining
screws.
Rated
Voltage
(V)
Rated
Current
(A)
Recommend
Wire Size
(AWG)
Model
US12 240 50 6
Table 5
NOTE:
When the Tronic 3000C Pro is not within
sight of the electrical circuit breakers, a
circuit breaker lockout or additional local
means of disconnection for all non
grounded conductors must be provided that
is within sight of the appliance. (REF NEC
422.31)
Rubber
Sleeve
Ground

Table of Contents