10 | Installation US
6 720 647 088 (2011/09)
4.4 Electrical connections
B Strip back the insulation on the power wires about 3/
8". Any insulation on the ground should be stripped
back about 3/4".
B Feed the cable through the cover bottom or backplate
entry grommets, as appropriate.
B Connect the cables to the terminal block and ground
stud (Fig. 3):
Fig. 3 Cable termination
B Make sure that all the terminal block screws are
tightened securely. Loose connections can cause
wires to neat up.
B Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut
should be tightened securely.
B Attach the front cover and tighten the retaining
screws.
Rated
Voltage
(V)
Rated
Current
(A)
Recommend
Wire Size
(AWG)
Model
US12 240 50 6
Table 5
NOTE:
When the Tronic 3000C Pro is not within
sight of the electrical circuit breakers, a
circuit breaker lockout or additional local
means of disconnection for all non
grounded conductors must be provided that
is within sight of the appliance. (REF NEC
422.31)