INSTRUCTIONS FOR USE
Caution! Federal (USA) law restricts this device
to sale by or on the order of a physician

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Boston Scientific Swiss LithoCast Trilogy FT-235 and is the answer not in the manual?

Boston Scientific Swiss LithoCast Trilogy FT-235 Specifications

General IconGeneral
Device CategoryMedical Equipment
Device TypeLithotripter
ManufacturerBoston Scientific
Patient TableIntegrated
Shock Wave Rate1-2 Hz
Weight1500 kg

Summary

WARNING

INSTALLATION

INSTALLING THE CONSOLE

Steps to place the console, remove protective film, and install stone catcher support.

FILLING THE COOLING SYSTEM

Steps to fill the cooling system with demineralized water, ensuring proper level.

CONNECTING THE CONSOLE TO THE EQUIPOTENTIAL CONDUCTOR

Connecting the equipotential conductor for electrical safety and potential equalization.

INSTALLING THE PEDAL

Connecting the pedal cord to the console and ensuring proper placement.

INSTALLING THE STONE CATCHER

Steps for installing the single-use stone catcher and the in-house aspiration system.

CONNECTING THE STERILIZED HANDPIECE TO THE CONSOLE

Connecting the sterilized handpiece to the console, ensuring the connector is dry.

CONNECTING THE POWER CORD

Connecting the device to a protected mains power supply and verifying voltage.

INSTALLING A PROBE ON THE HANDPIECE

Selecting and installing the appropriate probe onto the handpiece using a torque wrench.

GETTING STARTED

STARTING THE DEVICE

Steps to turn on the console, perform diagnostic tests, and prepare for use.

ADJUSTING THE PARAMETERS

Accessing and configuring treatment parameters via the touch screen interface.

TREATMENT

FUNCTIONAL TESTS

Performing preliminary tests to ensure the device and components are working correctly before treatment.

PROBE INSERTION

Steps for introducing and positioning the probe within the endoscope and contacting the stone.

TREATMENT SETTINGS

Configuring console parameters based on probe type and selecting pre-set treatments.

CUSTOM SETTINGS

Manually adjusting impact, ultrasound, and suction parameters for personalized treatment.

POST-TREATMENT PROCEDURE

CLEANING, DISINFECTING, AND STERILIZING

PRODUCT MAINTENANCE

TECHNICAL SUPPORT