16
P12 /P15 /P18
4. Technical Specifications
P15
Heating
Steam
Electric
Consumption for drying:
Drying time inc. reduction without Slimsorba
with Slimsorba
min.
min.
19
24
19
24
Elec. energy drying without Slimsorba
with Slimsorba
kWh
kWh
1.8
2.0
3.0
2.9
Saturated steam drying without Slimsorba
with Slimsorba
kg(lb)
kg(lb)
2.0(4.4)
2.0(4.4)
-
-
Cooling water drying without Slimsorba
12 °C (53.6 °F) with Slimsorba
l(US gal)
l(US gal)
65(17.1)
60(15.8)
65(17.1)
60(15.8)
Consumption for distillation:
Distilled solvent l(US gal) 25(6.6)
25(6.6)
Elec. energy distillation kWh -
3.6
Saturated steam distillation kg(lb) 5.4(11.9)
-
Cooling water for dist. (12 °C or 53.6 °F) l(US gal) 70(18.4)
70(18.4)
Consumption per cycle: *
El. energy without Slimsorba
with Slimsorba
kWh
kWh
2.0
2.2
6.8
6.7
Saturated steam without Slimsorba
with Slimsorba
kg(lb)
kg(lb)
7.4(16.3)
7.4(16.3)
-
-
Cooling water drying without Slimsorba
(12 °C or 53.6 °F) with Slimsorba
l(US gal)
l(US gal)
135(35.6)
130(34.3)
135(35.6)
130(34.3)
Compressed air (6 bar or 87 psi) l(US gal) 6(1.6)
6(1.6)