23
P12 /P15 /P18
5. Settings and Optimum Operating Values 5.
P18
Basic value:
Steam pressure (saturated steam) bar(psi) 4–5(58–72.5)
Steam temperature (max. permitted) °C(°F) 150(302)
Cooling water pressure bar(psi) 2-4(29-58)
Cooling water temperature, max. °C(°F) 25(77)
Compressed air bar(psi) 6(87)
Cage speeds:
Cleaning/ RPM 35
Spinning RPM 500
Reversing cycle (cleaning) sec. 10/1/10
Low level l(US gal) 45(11.9)
High level l(US gal) 90(23.7)
Pump pressure (max.) bar(psi) 2.5(36.2)
Filter surface, economy filter m
2
(ft
2
) 2.7(29.0)
Filter powder (only for machines without emission-
free still rake out system)
kg(lb)
1.2(2.6)
Tank I: optimum filling volume (high level) l(US gal) 90(23.7)
Tank III: optimum filling volume l(US gal) 90(23.7)
Detergent solution cooler:
Detergent solution thermal sensor:
Detergent solution cooler ON
°C(°F)
15–30(59-86)
Refrigeration technology:
Filling capacity, cooling agent R 404A kg(lb) 4.6(10.1)
Nozzle size: solvent cooling no. 03
Drying+ Reduction no. 06
High pressure control switch ON approx. bar(psi) 21(319)
High pressure control switch OFF approx. bar(psi) 26(377)
Low pressure control approx. bar(psi) 1(14.5)
Drying:
Cooling water regulator setting:
Adjust 4 – 6 min. after start of drying bar(psi) 20(290)
Temp. sensor, cage entry (gentle drying) °C(°F) 60(140)
Temp. sensor, cage exit °C(°F) 50(122)
Temp. sensor after cooler:
Control value, drying °C(°F) 40(104)
Control value, cycle end °C(°F) 15(59)
Safety thermostat, heater battery (elec. only) °C(°F) 110(230)