EasyManua.ls Logo

BÖWE P12 - Adsorption Filter Cartridge Maintenance

Default Icon
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84
P12 /P15 /P18
11. Maintenance 11.
Disposing of the machine
Drain cartridge filter (if existent).
Allow cartridge to drip dry and dispose of it.
Drain Economy filter
Remove, clean and dry filter discs
Empty water separator and safety separator (dispose of process water, decant solvent).
Empty out process water tank, dispose of process water.
Empty tanks.
Empty condenser.
Empty out solvent pump and sludge pump, do not leave any solvent residue in the base of the
pump
Empty and clean the still when it is cold, dispose of residues.
Pump cooling agent out of the refrigeration unit
(done by authorized customer service technician).
On machines with Slimsorba, remove carbon from the Slimsorba and
dispose of in special waste.
Close open solvent lines tightly when disassembling the machine.
You must completely remove all residues that could present a hazard to people and the
environment,
Observe safety regulations concerning the handling of solvent (see Point 2).