EasyManua.ls Logo

Bradford White ACCESSORY MODULE - Accessory Module Package Components; Accessory Module Components List

Bradford White ACCESSORY MODULE
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Package Components Accessory Module
-8-
Table 1
Accessory Module
Description Quantity
1A Plug-in Transformer 1
2A WV4460 Wire Harness 1
3A Transformer Wire Harness 1
4A WV8840 Wire Harness 1
5A Wire Holders 4
6A Installation & Operation Manual 1
7A Wiring Diagram Label 1
8A Diagnostic Label 1
9A Wire Ties 4
10A Screws 9
11A Accessory Module 1
NOTICE
The WV4460 wire harness must be used with gas controls with intermittent pilots. The WV8840
wire harness must be used with gas controls with standing pilots.
238-47880-00A
R1 C1 LK C2 NO NC D/1 R/ 2 C/3 A1 A2
ACCESSORY MODULE
R1 C1 LK C2 NO NC D/1 R/ 2 C/3 A1 A2
ACCESSORY MODULE
D
R
C
BK
W
R
BK BL BKBR R WBK BK Y
R
W
BK
BK
W
R
BK BL BKBR R WBK BK Y
R
BK
W
*WHEN CONNECTING LEAK SENSOR, REMOVE RESISTOR
BETWEEN C1 & LK.
**WHEN CONNECTING ANODE DEPLETION SENSOR, REMOVE RESISTOR
BETWEEN A1 & A2.
*WHEN CONNECTING LEAK SENSOR, REMOVE RESISTOR
BETWEEN C1 & LK.
**WHEN CONNECTING ANODE DEPLETION SENSOR, REMOVE RESISTOR
BETWEEN A1 & A2.
SEE INSTALLATION AND OPERATION MANUAL FOR MORE INFORMATION.
SEE INSTALLATION AND OPERATION MANUAL FOR MORE INFORMATION.
222-47463-01
222-47463-02
222-47464-01
222-47464-02
222-47465-01
222-47465-02
222-47466-01
222-47466-02
222-46402-01
222-46402-02
222-46990-01
222-46990-02
222-46991-01
222-46991-02
FOR USE WITH THE FOLLOWING GAS VALVES:
222-45613-01
222-45613-02
222-45614-01
222-45614-02
FOR USE WITH THE FOLLOWING GAS VALVES:
LED on continuously . Power on (no fault).
One flash and three second pau se. Leak alarm faul t. Water shut-off valve ope n.
Two flashes and three second p ause. Leak alarm faul t. Water shut-off valve closed.
Three flashes and three sec ond pause. Anode de pletion alarm or not c onnected.
Four flashes and three sec ond pause. Leak se nsor malfunction.
Five flashes and three sec ond pause. Gas valve missing/no t connected.
RED LED strobe ( quick flashes). Hardware error.
AMBER
AMBER
AMBER
RED
RED
GREEN
COLOR PATTERN
ACCESSORY MODULE STATUS LED STATUS
See Installation and Operation Instructi on Manual for probable c auses
associated with each c ontrol status code.
ACCESSORY MODULE DIAGNOSTIC CODES
238-47879-00A