Parameter 16 - Hot water temperature
Setting range: 10.0 °C to DHW maximum limit
Factory setting: 63 °C
This parameter determines the desired domestic hot water
temperature when operated in operating modes PARTY, HEA-
TING and SUMMER and serves as a base value for the dome-
stic hot water temperatures in the automatic programs.
Application:
Determination of the domestic hot water standard temperature
- simple adjustment for all domestic hot water specifications in
case of other situations of use (e.g. change of tenent or owner)
6633..00
DDHHWW
PPAARRAAMMEETTEERR 1166
mm
°C
Page GB-28