Lists specific A5S1 sensor models and their associated signal ranges.
Details speed sensors for hazardous areas, based on Differential-Hall-Effect Principle.
Lists TÜV certifications for IEC 61508, ISO 13849, and IEC 62061 standards.
Provides guidance on how to mount the sensor, including radial and frontal scanning.
Details how to adjust the sensor alignment with the profile edges for optimal performance.
Explains the correct alignment of the sensor with the scanning profile, including permissible deviations.
Specifies the recommended air gap between the sensor and the rotating profile based on size.
Lists maximum fastening torques, wrench sizes, and nut thicknesses for sensor installation.
Illustrates the pin arrangement for the sensor's connector plug.
Describes how the sensor indicates direction of rotation using a constant signal level.
Details the two phase-shifted frequency signals provided by specific sensor models.
Explains the rectangular pulse shape and voltage levels of the sensor's output signal.
Details certifications for IEC 61508 (SIL 3), ISO 13849 (PL e), and IEC 62061 (SILCL 3).
Presents the TÜV NORD SIL 3 Certificate for the A5S Series Hall-effect sensors.
Provides the EU Declaration of Conformity for the A5S1...-n series sensors.
References technical data and certificates relevant to hazardous area operation.
Details the ATEX certification for the input circuit, including type examination certificate.
Lists types of certifications for hazardous areas (ATEX, IECEx, NEC/CEC, EAC Ex).
Shows the ATEX Type Examination Certificate (CML 14ATEX4076X) for the A5S sensor.
Presents the IECEx Certificate of Conformity (IECEX CML 14.0030X) for the A5S sensor.
Details the NEC/CEC Certificate of Conformity (LR 1323) for North American hazardous locations.
Shows the EAC Ex TR CU Certificate for products used in the Eurasian Customs Union.
General instructions for safe connection, maintenance, and operation of the sensors.
Details the sensor's compliance with EMC regulations and standards.
Warns about metallic abrasion affecting sensor performance and how to mitigate it.
Covers safety for installation, commissioning, and initial recalibration procedures.
Covers safety aspects during operation, maintenance, and recalibration needs.
Lists EU directives and harmonized standards to which the sensors conform.
Specifies the required DC supply voltage range and current consumption.
Describes the sensor's rectangular pulse output, amplification, and load capacity.
Defines the maximum signal frequency range for different A5S sensor models.
Details cable specifications for signal transmission, including impedance and capacitance.
Specifies protection class and IP code for the sensor housing.
Lists available connection types: screw-plug, PVC, or Teflon® cables.
Refers to certificates for information on permissible ambient operating temperatures.
Describes available installation threads and nominal lengths for sensor dimensions.
Provides diameters for various BRAUN PVC and Teflon® sensor cables.
Lists optional accessories such as connector cables and standalone connectors.
Details useful lifetime, proof test interval, and replacement recommendations for A5S sensors.