EasyManuals Logo

Braun BP4900 User Manual

Braun BP4900
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
8
9
Morning Average (for BP5900 only)
Press the “Average (3) button again into “Morning
Average
mode, the morning measurements in
memory within past 7 days will show on LCD.
If there is no data in memory within past 7 days,
will
show on LCD.
Evening Average (for BP5900 only)
Press the “Average (3) button once again into “Evening
Average
mode, the evening measurements in memory
within past 7 days will show on LCD.
If there is no data in memory within past 7 days,
will
show on LCD.
Erasing Data
Press the “Memory
M
(2) button into Memory mode.
Press and hold the “Mode
(5) button and then press the
“Set
(4) button, all the stored data will be erased and
CLR will show on screen.
To check if the data was erased, press the “Memory
M
(2)
button. No data should show up on screen, but date, time
and M:00.
Morning Hypertension Setting (for BP5900 only)
Morning Hypertension symbol will appear when Morning Average is above your
pre-congured Systolic rate and/or pre-congured Diastolic rate, AND/OR one or both of
these measurements is 20% or more above Evening Average.
** Your pre-congured Systolic / Diastolic should be decided between you and your
doctor or healthcare provider.
After setting Date and Time, press “Mode
(5) button
into “Morning Hypertension
setting mode “- - ” on
Systolic position will ash for Systolic setting.
Press “SET
(4) button, LCD will appear 135 mmHg for
SYS as the internal pre-set value, then press “Set
button
repeatedly to set his own value (Range from 70~250 mmHg)
Press “Mode
(5) button again into “Morning
Hypertension
setting mode “ - - ” on Diastolic position
will ash for Diastolic setting.
Press “SET
(4) button, LCD will appear 85 mmHg for DIA
as the internal pre-set value, then user presses “SET
button to set his own value (Range for DIA is
40 ~ 115 mmHg).
User can press START/STOP
(1) button to exit setting
mode and go back to standby at any step.
Irregular Heart Beat Detector (for BP5900 only)
The appearance of this symbol signies that a certain pulse irregularity was detected
during the measurement. Talking, moving, shaking or an irregular pulse during the
measurement can result in the appearance of this icon. Usually this is not a cause for concern,
however if the symbol appears often, we recommend you seek medical advice. The device does
not replace a cardiac examination, but serves to detect pulse irregularities at an early stage.
As a safeguard, we recommend that if you have arrhythmias such as atrial or ventricular
premature beats, artial brillation or any other special conditions, you should check with your
physician before using your blood pressure monitor.
Low Battery Indicator
When the low battery indicator ashes on the display, it means the battery is low and
the four batteries need to be replaced with Alkaline LR6 (AA) batteries.
** After replacing batteries, the Blood Pressure Monitor will go into TIME-SETTING mode automatically
and show the last measurement time on screen. Please SET the current DATE / TIME before taking the
next measurement to get correct AVERAGE result.
Storage and Cleaning
• Always keep the unit in the carrying case after its use.
Do not put the item directly under the sunlight, in high temperature or humid and dusty places.
Do not store in extremely low (less than -4°F (-20°C)) or high (more than 140°F (60°C))
temperature.
Use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece
of dry cloth to wipe it dry. Use a piece of dry cloth to wipe the cu when it is dirty.
• Do not use any strong cleansers to clean it.
When the unit is not to be used for a long time, remove the batteries.
(Batteries may leak or cause harm).
What to do if …
Problem Reason Solution
Heart Rate
Symbol
Appears in the measurement
condition and ashes when
pulse is detected.
Measurement in progress, remain quiet.
Low Battery
Indicator
Appears when the battery
voltage is excessively low or
the positions of the batteries
are incorrect.
Replace all four batteries with new ones.
Insert the batteries in the correct
positions. Be aware of +/- positions.
Measuring
Error
Appears when the accurate
blood pressure and pulse
could not be obtained.
Press “Start/Stop” button again and
remeasure.
Check if cu is wrapped according to
instructions.
Check that there are no kinks in tube.
• Check palm if exerting eort.
Check if talking or moving during
measurement.
• Check if posture is correct.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Braun BP4900 and is the answer not in the manual?

Braun BP4900 Specifications

General IconGeneral
BrandBraun
ModelBP4900
CategoryBlood Pressure Monitor
LanguageEnglish

Related product manuals