3202 - 13
BINC Rev: 4/97 Service Documentation
Service Information
BAG Rev: 2/97 3202
Measuring points PCB In case the switching contacts on the PCBs (5 and 36) are closed and
a connecting wire at the motor (for example +) is taken off for the
measuring process.
N L Mains voltage
+ - 165-170 Volts DC voltage (intermittent 6-10 kHz)
P M 165-170 Volts DC voltage (constant)
N ~ Mains voltage
Function Check Check the appliance in all switching positions and, if necessary,
attach the available supplementary parts.
Check the security locks with and without the complete bowl resp.
mixer.