7712206-User Manual-EN-2019-9 7 | 22
Install the 3 legs of the malt pipe using an allen key. Take note that the latches must be
installed as shown below, and the wing nut must be used on the outside of the malt pipe.
Alternatively you can use the included hex nut. Install the silicone leg protectors to avoid
scratching the bottom of the main tank during use.
Combined leg and holder for malt pipe
Check for leaks
When filling the tank with water for the first time, make sure the taped threads on the
pump and the sensor and heating elements gaskets are not leaking. Tighten if necessary.
Also check that all TC clamps are tightly installed. The TC clamps might require tightening
after use, due to the variations in temperature.
The filter
The filter included is made from expanded metal and might have some tension. Make sure
the filter is flat. Flatten by hand if necessary. The filter should be cleaned before use to
remove any residue from production.
Cleaning
The system should be thoroughly cleaned before use to remove polishing compounds and
flux from the production process. Use Trisodium Phosphate (TSP) or other chemicals
designed for this type of cleaning. Use a microfiber cloth to wipe all surfaces clean.