EasyManua.ls Logo

Brezza FRE125 - User Manual

Brezza FRE125
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AIR COOLER
INSTRUCTION MANUAL
NEW WITH UV DEVICE FOR WATER STERILIZATION
125

Questions and Answers

Summary

Environmentally Friendly Disposal

Safety Warnings

UV Lamp Safety Advisory

Warns about UV ray hazards and prohibits opening the machine or UV lamp cover.

Product Features Overview

Cooling and Airflow Capabilities

Describes the cooling mechanism, 6 fan speeds, and wide air output range for comfort.

Water Tank and Filtration System

Highlights the built-in water tank and detachable, easy-to-clean filtration mesh.

User Interface and Control

Covers remote control, touch panel operation, and memory function for user convenience.

Timer and UV Sterilization Integration

Explains the 1-24 hour timer setting and the health benefits of the built-in UV lamp.

Important Precautions

Maintenance and Cleaning

Filtration Mesh Cleaning

Step-by-step guide on removing, cleaning, and drying the filtration mesh.

Water Tank Cleaning Procedure

Instructions for adding water and draining dirty water from the tank.

Appliance Body Cleaning

Method for cleaning the appliance's exterior with a damp cloth.

Guarantee Information

Overview

The Brezza 125 is an air cooler designed to provide a comfortable environment in hot weather. It features a built-in UV lamp for water sterilization, aiming to prevent the formation of bacteria and mold, including legionella. This UV device is a distinctive health-focused feature, with the UV lamp lasting for an average of 7000 hours.

Function Description:

The Brezza 125 operates by cycling water to blow cool air, effectively lowering the surrounding temperature. It incorporates an evaporative cooling function, where a water pump and the UV lamp work together to sterilize the water. This process helps to prevent the development of pathogens caused by stagnant or contaminated water. The unit also includes an ionizer function, which releases negative ions into the air to improve air quality. An alarm system provides a sound signal when the water tank is empty. The display indicates the outlet air temperature.

Usage Features:

The air cooler offers a wide range of air output with a 100-degree angle and six fan speeds: Normal (HIGH-MID-LOW) and Sleep (HIGH-MID-LOW). It can be controlled via a remote control with a 6-meter range and a 120-degree wide receiver, or directly through its touch panel. The touch panel is designed for ease of use with an elegant aesthetic. A memory function allows the unit to recall its last working status, which is retained until the power supply is completely disconnected. The timer can be set for 1 to 24 hours, increasing in 1-hour intervals, with the digital tube displaying the remaining time.

When first turned on, the unit starts in MID speed for 3 seconds and then reverts to its memorized status. If it's the first time using the unit, it will start in MID speed for 3 seconds and then operate at LOW. The "NORMAL" mode provides a fixed speed, while the "SLEEP" mode offers a lower, quieter, and softer wind speed. In sleep mode, if there's no interaction with the touch buttons for 3 minutes, the indicator lights and digital display will dim.

The unit features both left and right air swing and up and down air swing functions, which can be activated and canceled with a single press of their respective buttons. To use the cooling function, the water tank must be filled, ensuring the water level is between the MIN and MAX lines. It is recommended to change the water and clean the tank frequently, as dust and dirt can accumulate. For optimal performance in the hottest weather, ice can be added to the water. Water-based scented essences can also be used to distribute scented air, but oil or soap-based essences should be avoided to prevent filter clogging.

Maintenance Features:

The Brezza 125 is designed with a built-in water tank and a detachable filtration mesh for easy cleaning. The filtration mesh should be cleaned frequently, as dust and dirt can clog it and affect performance. To clean the mesh, remove the plug from power, loosen the screw, pull the handle upwards, and then clean the mesh with mild detergent and a soft brush. Ensure the mesh is completely dry before reinstallation.

For cleaning the water tank, remove the power plug, add water through the front inlet, and then drain the dirty water from the back outlet. The body of the unit can be cleaned with a cotton cloth and a little mild detergent. It is crucial to unplug the unit from the outlet before any cleaning and to avoid getting water on the control panel.

To maintain the UV lamp's effectiveness and prevent lime buildup, it is suggested to run a lime washing cycle at least once a year. This involves adding one liter of white vinegar to the water tank and activating the COOL function until the tank is completely empty. After this, the tank should be refilled with water only, and the procedure repeated. If the UV lamp needs replacing, contact Rubisolis.

Safety Precautions:

Users are explicitly warned not to open the machine or the UV lamp cover, as the ultraviolet ray is harmful to human eyes and skin. All maintenance, water filling, and cleaning operations require the device to be turned off and unplugged from the electric socket. The appliance should not be used if the electric cable is damaged, and any repairs should be handled by a service center or qualified personnel. Children should be supervised and instructed on safe use, and they should not play with the appliance or perform cleaning and user maintenance without supervision. It is important to keep the appliance dry and avoid using it with wet hands. Objects should not be inserted into the air port while the appliance is operating, and the unit should not be covered with flammable materials. The appliance should be placed on a flat surface, and the cellulose panels should be perpendicular to the floor to prevent water sprays from the fan.

Brezza FRE125 Specifications

General IconGeneral
RefrigerantR32
TypeSplit AC
Energy Rating5 Star
Power Requirement230V, 50Hz
Operating Temperature16°C to 43°C
Warranty1 Year on Product, 5 Years on Compressor

Related product manuals