1 to 50: the output value changing step for each
pulse. No decimal points. Rotating the knob one turn
(360 degree) equals 20 pulses. Can be ten times 10 x
(1 to 50).
-999 to +999. Not recommend to set this code if
output accuracy is normal. if it must be set, this
function is only for professionals.
* Before entering into F002 parameters setting status, user must rotate the knob to enter password: + - - +
Table 1.2
* When doing F006, F007, F008 output precision calibration, user must have a high precision multimeter to calibrate
it, and DO adjust output to let the screen display 12mA or 20mA or -10V, 0V, 10V, etc. firstly.
Battery Information
* For No Battery inside type, user can add a 3.7V rechargeable battery by doing
DIY.
The battery information recommended below:
• Higher or lower than 1000mAH, 3.7V voltage, Lithium battery.
• Size: Length 50mm x Width 35mm x Thickness ≤5mm or similar size
• Connector: XH2.54mm 2pin connector.
• Thickness ≤5mm, Flat square shape.
• Only professional developer is recommended to do that DIY.