7 Technical data of the P 1000 cartridge
Operating pressure 2 bar to max. 8.6 bar
Water intake temperature 4°C to 30°C
Ambient tem-
perature for
operation 4°C to 40°C
storage/transport –20°C to 50°C
Nominal service flow
(acc. to DIN 18879)
60 L/h
Capacity up to carbonate hardness
8.5 °dH at setting “+”
1000 L
Capacity from carbonate hardness
8.5 to 17 °dH at setting “++”
500 L
Pressure loss by nominal service flow 0.2 bar
Empty filter cartridge volume 1 L
Weight (dry/wet) 1.0 kg/1.4 kg
Dimensions
(Width/Depth/
Height)
Filter system
(filter head with filter
cartridge)
117 mm/108 mm/265 mm
Filter cartridge 108 mm/108 mm/259 mm
Installed dimensions
(vertical installation
with wall mounting
bracket)
137 mm/130 mm/265 mm
Operating position Horizontal and vertical
Water inlet connection G3/8"
Water outlet connection G3/8"
8 Troubleshooting
A No water flow
Cause: Water intake closed.
Troubleshooting: Open the water intake at the upstream shut-off
valve or by closing the locking handle (3) on the
filter head. Check hoses for kinks.
B No or low water flow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault continues,
check the filter system and filter cartridge and
replace if necessary. Check hoses for kinks.
Cause: Filter head not mounted in direction of water
flow / hoses wrongly connected.
Troubleshooting: Dismantle filter head and hoses and install in
direction of water flow (chapter 3.4).
C Leak
Cause: Screwed connections not fitted correctly.
Troubleshooting: Check mains pressure. Check all screwed
connections and mount as described in
chapter 3.4.
D LED not blinking
Cause: Battery empty
Troubleshooting: Change the battery (usually after 3 years)
Cause: Battery wrongly installed
Troubleshooting: Turn the battery around
Cause: BRITA electronic cartridge exchange indicator
wrongly installed
Troubleshooting: Turn it around so that the side with the battery
faces the BRITA logo on the lever
E LED blinking red
Cause: Time to change the filter cartridge
Troubleshooting: Change the filter cartridge (chapter 4) and reset
the battery (chapter 5)
If you are still experiencing issues, please call BRITA Customer
Care – see back page for more details.