26
Performance Data
VOCs (by surrogate testing using
chloroform)
Maximum Permissible
Concentration
Effluent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
Haloketones (HK)
1,1-dichloro-2-propanone NA 7.2 μg/L 0.1 μg/L 99%
1
,1,1-trichloro-2-propanone NA 8.2 μg/L 0.3 μg/L 96%
Heptachlor 0.4 μg/L 25 μg/L 0.01 μg/L >99%
Heptachlor Epoxide 0.2 μg/L 10.7 μg/L 0.2 μg/L 98%
Hexachlorobutadiene NA 44 μg/L 1.0 μg/L 98%
Hexachlorocyclopentadiene 50 μg/L 60 μg/L 0.002 μg/L >99%
Lindane 0.2 μg/L 55 μg/L 0.01 μg/L >99%
Methoxychlor 40 μg/L 50 μg/L 0.1 μg/L >99%
Pentachlorophenol 1.0 μg/L 96 μg/L 1.0 μg/L 99%
Simazine 4.0 μg/L 120 μg/L 4.0 μg/L 97%
Styrene 100 μg/L 150 μg/L 0.5 μg/L >99%
1,1,2,2-Tetrachloroethane NA 81 μg/L 1.0 μg/L 99%
Tetrachloroethylene 5.0 μg/L 81 μg/L 1.0 μg/L 99%
Toluene 1,000 μg/L 78 μg/L 1.0 μg/L 99%
2,4,5-TP (silvex) 50 μg/L 270 μg/L 1.6 μg/L 99%
Tribromoacetic acid NA 42 μg/L 1.0 μg/L 98%
1,2,4-Trichlorobenzene 70 μg/L 160 μg/L 0.5 μg/L >99%
1,1,1-Trichloroethane 200 μg/L 84 μg/L 4.6 μg/L 95%
1,1,2-Trichloroethane 5.0 μg/L 150 μg/L 0.5 μg/L >99%
Trichloroethylene 5.0 μg/L 180 μg/L 1.0 μg/L >99%
Chloroform (THM)
80 μg/L 300 μg/L 15 μg/L 95%
Bromoform (THM)
Bromodichloromethane (THM)
Chlorodibromomethane (THM)
Xylenes (total) 10,000 μg/L 70 μg/L 1.0 μg/L 99%
This system has been tested according to NSF/ANSI standards for the reduction of substances listed above. The con-
centration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 58, 401 and 473.
Testing was performed under standard laboratory conditions. Actual performance may vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmo-
sis treated water under operating conditions that approximate typical daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to
the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank
is bypassed.
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after
the system. This system is certified for cyst reduction, and may be used on disinfected water that may contain filterable
cysts.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in
combination, measured as N, and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 40 psig
(276 kPa) or greater.
FILTER PERFORMANCE DATA
Flow Rate 0.9 gallons per minute (3.4 liters per minute)
Capacity 230 gallons (871 liters)