Page 1
ALLURE
®
QS2 SERIES
RANGE HOOD
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society of Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size
of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
ALLURE
®
QS2 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. For best capture of cooking impurities, your range hood should
be mounted so that the top of the hood is 24-30” above the
cooking surface.
5. Please read specification label on product for further information
and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location
“PREPARE THE HOOD”
Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD”
Secure hood to cabinet and ductwork - install bulbs and filters
“OPERATION”
How to use the hood controls
“CLEANING”
Keep your hood in top working condition
“SERVICE PARTS”
Part numbers and exploded view of hood components
“WARRANTY”
One-year limited warranty and how to contact us
NOTE If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
Patent No.:
US D450, 829 S
!
FOR DOMESTIC COOKING ONLY
!
Register your product online at: www.broan.ca/register

Other manuals for Broan ALLURE QS2 Series

Question and Answer IconNeed help?

Do you have a question about the Broan ALLURE QS2 Series and is the answer not in the manual?

Summary

Prepare Hood Location

Determine Duct Discharge Type

Guide for selecting vertical or horizontal ductwork configuration.

Diagrams for Ductwork and Electrical Cutout Placement

Diagrams show ductwork and electrical cutout placement for cabinets.

Prepare the Hood

Remove Hood Filters

Instructions to remove filters from the hood assembly.

Remove Bottom Cover and Screws

Steps to detach and set aside the bottom cover and its screws.

Remove Damper;Duct Connector

Instructions to remove the damper/duct connector for installation.

Install Electrical Cable Clamp

Install electrical cable clamp by removing appropriate wiring knockout.

Remove and Reinstall Light Panel

Detaching the light panel and reassembling it.

Prepare Air Chute and Baffle

Steps to remove, rotate, and reinstall the air chute and baffle.

Prepare for Non-Ducted Installation

Attach a Performance Ring to the blower wheel for non-ducted installations.

Remove Duct Knockouts

Remove knockouts for duct connection based on installation type.

Prepare Horizontal Discharge Knockout

Remove the plate for horizontal discharge knockout.

Attach Damper;Duct Connector

Attach damper/duct connector for ducted installations.

Connect Wiring

Connect House Wiring to Hood

Connect the 120 VAC house wiring to the hood unit.

Secure Wire Connections

Connect black to black, white to white, and ground wires, securing cable clamp.

Install Hood

Hang Hood and Secure Mounting Screws

Hang the hood on mounting screws and tighten securely.

Replace Bottom Cover

Reinstall the bottom cover of the hood.

Connect Ductwork to Hood

Connect the ductwork to the hood using duct tape for airtight joints.

Install Light Bulbs

Install specified halogen or incandescent bulbs.

Test Hood Operation

Replace filters, turn on power, and test the hood's functionality.

Operation

Non-Ducted Filter Usage

Notes on non-ducted filters and optimal speed settings.

Fan and Light Controls

Instructions on using the push button switches for fan and light.

Heat Sentry Feature

Explanation of the Heat Sentry feature and its indicators.

Fuse Information and Replacement

Details about the hood's fuse and how to replace it.

Cleaning

Cleaning Aluminum Mesh Filters

Instructions for cleaning aluminum mesh filters, which are dishwasher safe.

Cleaning Charcoal Filters

Guide for cleaning charcoal filters using a damp cloth.

Cleaning the Hood Surfaces

Instructions to wipe down hood surfaces with a damp cloth and mild detergent.

Service Parts

Warranty Information

Broan ALLURE QS2 Series Specifications

General IconGeneral
DuctingDucted
Voltage120V
InstallationUnder Cabinet
TypeUnder-Cabinet
Width30 inches
FinishStainless Steel
Depth19.75 inches
MaterialSteel