MODEL
331H
or 332H
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
10" ROUND ELBOW
DUCT
OPENING
COVER PLATE
MODEL
331H
or 332H
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
DUCT
OPENING
COVER
PLATE
MODEL 331H or 332H
EXTERIOR BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND
DUCT
SOFFIT
24" or 27"
18"
ROUGH-IN
PLATE
DUCT
OPENING
COVER PLATE
READ AND SAVE THESE INSTRUCTIONS
FOR USE WITH RANGEMASTER HOODS AND ECLIPSE DOWNDRAFT VENTILATORS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall, or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum for Model 332H or 3 AMPS minimum
for Model 331H.
Important-when using Model 332H with the Broan Eclipse
Downdraft Models 2830-A or 2836-A: Purchase a
#97011927 Speed Control Kit from your Broan distributor
to replace the speed control in your downdraft.
1. Locate the blower so the length of the duct run and number of
elbows and transitions needed are kept to a minimum.
Please note - when using blower with the Broan Eclipse
Downdraft: The downdraft has a 3¼" x 10" discharge.
Transitions are available to connect it to the 10" round inlet
on this exterior-mounted blower.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
331H 120 2.4 600 10 " DIA.
332H 120 5.7 900 10" DIA.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 3
MODELS 331H & 332H
EXTERIOR MOUNTED BLOWER
SPECIFICATIONS
PLAN THE INSTALLATION
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
2. Where possible, blower should be centered between wall
studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be running
through the wall.
4. Be sure that there is enough space for any transitions that may
be needed between the blower and the connecting ductwork.
5. For best performance, locate transitions nearest to ventilator
(i.e. downdraft).
NOTE: Horizontal discharge requires relocation of the duct open-
ing cover plate. See hood manual for instructions.
Page 1
Question and Answer IconNeed help?

Do you have a question about the Broan NuTone 331H and is the answer not in the manual?

Summary

WARNING

General Safety and Installation Precautions

Key safety instructions for fire, shock, injury, and proper installation.

CAUTION

Usage and Electrical Cautions

Guidelines for general use, motor care, and electrical requirements.

PLAN THE INSTALLATION

General Installation Planning

Advice on locating the blower for optimal duct runs and avoiding obstructions.

Typical Roof Mounted Installation

Diagram and notes for typical roof-mounted installations.

Typical Wall Mounted Installation (Vertical Discharge)

Diagram and notes for typical wall-mounted installations with vertical discharge.

Typical Wall Mounted Installation (Horizontal Discharge)

Diagram and notes for typical wall-mounted installations with horizontal discharge.

SPECIFICATIONS

PREPARE THE INSTALLATION LOCATION

Roof Installation Preparation

Steps for preparing the roof opening and marking for installation.

Wall Installation Preparation

Steps for preparing the wall opening and marking for installation.

PREPARE THE BLOWER

Blower Preparation Steps

Instructions for unpacking and preparing the blower unit for installation.

INSTALL THE BLOWER

Roof Installation Steps

Detailed steps for installing the blower on the roof.

Wall Installation Steps

Detailed steps for installing the blower on the wall.

USE AND CARE

Cleaning Instructions

Procedure for safely cleaning the blower and housing.

Motor Lubrication Information

Information regarding motor lubrication requirements.

SERVICE PARTS

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan NuTone 331H Specifications

General IconGeneral
BrandBroan
ModelNuTone 331H
CategoryBlower
LanguageEnglish