Do you have a question about the Broan QT140E and is the answer not in the manual?
Use the unit only as intended by the manufacturer and contact them for questions.
Switch off power at the service panel and lock it to prevent accidental power.
Installation and wiring must be done by qualified persons per codes and standards.
Sufficient air is needed for fuel-burning equipment to prevent backdrafting.
Do not damage electrical wiring or other hidden utilities when cutting or drilling.
Ducted fans must always be vented to the outdoors for proper operation.
Acceptable for use over tub/shower when connected to a GFCI-protected branch circuit.
This unit must be properly grounded to ensure electrical safety.
For general ventilating use only; do not exhaust hazardous or explosive materials.
Designed for ceilings up to 12/12 pitch; duct connector must point up. DO NOT MOUNT IN A WALL.
Keep drywall spray, construction dust, etc., off the power unit to prevent damage.
Please read the specification label for further information and requirements.
Lower or remove grille, vacuum interior with dusting brush attachment for quiet operation.
Motor is permanently lubricated; replace blower assembly if bearings make noise.
Use an on/off switch or speed control to operate the ventilator.
Covers defects in materials/workmanship for three years from purchase date.
Excludes bulbs, fuses, filters, ducts; limits liability for consequential damages.
Notify Broan-NuTone with defect details, model number, and proof of purchase.
Illustrates housing mounted to standard ceiling joists.
Shows mounting to I-joists using a provided spacer block.
Depicts housing mounted to ceiling trusses.
Do not install above or inside a cooking area.
Instructions on insulating housing and sealing duct joints.
Use 6-in. or 4-in. round ductwork with roof or wall caps.
Bend housing tabs out to 90 degrees using pliers.
Secure housing to joist using screws or nails, with spacers for I-joists.
Snap connector onto housing, ensuring flap is closed and flush.
Connect 6-inch or 4-inch ductwork and seal connections for air tightness.
Shows wiring connections for ON/OFF switch, switchbox, and unit.
Run 120 VAC house wiring, use UL connectors, and connect wires as shown.
Install ceiling material and cut out around the housing.
Squeeze grille springs and insert them into the tabs on each side.
Push the grille firmly against the ceiling to secure it.
Replacement parts can be ordered on the Broan website.
List of service parts with key numbers, part numbers, and descriptions.
Instructions on how to remove the blower assembly from the housing.
| Airflow | 140 CFM |
|---|---|
| Noise Level | 1.5 Sones |
| Duct Size | 4 inches |
| Light Bulb Type | Incandescent |
| Light Wattage | 100 Watts |
| Voltage | 120V |
| Housing Material | Galvanized Steel |
| Mounting Type | Ceiling |