BROOD Nitro V2PX Operations Manual V2.2 Eng
6
7. After use of an espresso cleaner, flush the unit with clean water as done in step 1. Then pull
the handle to let the Nitro Coffee machine release the remaining liquid.
8. Unscrew the entire tap at the base. Pull out the silicon tube pictured below and rinse well with
water. Re-insert the silicon tube and screw back the tap once complete. Note that the top part
of the silicon tube is blue and this should be at the further end inside the machine.
9. Switch of the air compressor and pull the handle again. This will release the pressure. Keep the
intake tube connected throughout.
6. Troubleshooting
Problem 1. I am not happy with the quality of my cascade
Remedy:
A) There may be ice in the tubes. It blocks the nitrogen from infusing.
1. Unplug the Nitro Coffee machine and wait 15 minutes. Repeat until the Nitro Coffee
machine starts pouring a cascade again.
B) There might be too much air entering the intake tube. This causes large bubbles to pour out at
the tap.
1. Tighten all connections to make sure there aren’t any air bubbles flowing through the
tube. Make sure that air isn’t being pulled from your source - the non-pressurized
container.
Problem 2. Nothing is pouring when I pull the tap
Remedy:
A) Make sure that all connections are connected firmly and that the air compressor is on.
B) If liquid is flowing through the tube before the pre-filter, yet nothing flows after the pre-filter,
then the pre-filter needs to be cleaned.
1. Disconnect the pre-filter and unscrew it for inspection. Use tools if necessary as it is
tightly screwed. Clean the internal net and then reattach the cap. Reattach the pre-
filter to the intake tube.
C) There might be a blockage inside the Nitro Coffee machine from the following:
1. Ice.
i. Unplug the Nitro Coffee machine entirely from the power supply and wait 15
minutes. Repeat until the Nitro Coffee machine starts to work again
2. Or, unfiltered liquid that has a lot of sediment or coffee residue.
i. Complete step 8 in the cleaning section (5). Check to see if there is a blockage.
ii. Test to see if the Nitro Coffee machine pours.
iii. If not, there may be a bigger blockage in the liquid pump. You will need to
unscrew the stout.
iv. Remove the BiB Adaptor and place a hose at the far end of the intake tube.
v. Turn the air compressor on.