NO.
IN
CHAPTER
8
PROBABLE
CAUSES
REPLACEMENt
FLOWCHART
AND
CHECK/
ADJUSTMENT
I
REPAIR
PAR15
··".
ERROR
STATUS
#4
5.
AJ
r valve defective
(a)
Unplug
connector
P1
of the control box,
Air
valve
The presser plate
then
measure the resistance.
will
not rise when
If
it
is
not
approx.
400
0 between pins 1
the presser plate
1(QJ@©
9
and 10. and between pins 2 and 10,
the
lifter switch
is
air
valve
is
defective.
stepped
on.
@©(QJ
:1
[9
(Q)@(Q]
4[Q)©©
12
P1
For
solenoid specification
(BAS~304A
and 311A)
4.
Mafn
PCB
defectiv~
(a} Refer
to
#2,
2(a).
Main
PCB
+
(b) Step on the presser plate
lifter
switch
while
pressing
STEP
BACK
switch.
3 9
If
an error code appears on
the
ERROR
~00
. indicator,
the
main
PCB
is
not defective.
(c)*
Unplug
connector
P1
of
the
control box,
00~
tum
on
the
power, then measure
the
voltage of J 1 while stepping
on
the
start
0
switch.
If
It
is
not approx.
10
VDC
1
7
between pins 3
(+)and
4 (·),the main
circuit board
Is
defective.
P1
-
S.
Air valve defective
(a)
Unplug connector
P1,
then measure
the
Air
valve
resistance.
If
it
is
not approx. s ohms between pins 3
9
3
and 4, the solenoid
is
defective.
000
[ooo
000
7
1
-18-
From the library of: Superior Sewing Machine & Supply LLC

Other manuals for Brother BAS-311A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother BAS-311A and is the answer not in the manual?

Brother BAS-311A Specifications

General IconGeneral
BrandBrother
ModelBAS-311A
CategorySewing Machine
LanguageEnglish

Related product manuals