EasyManua.ls Logo

BRUEL & KJAER 1024 User Manual

BRUEL & KJAER 1024
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BROEL
&
KJ.ER
NC2rum
- Denmark
Service Instructions
Sine
-
Random
Generator
Consisting
of:
tv'.eter
Circuit
Output
Amplifier
Oscillator
Compressor
Position
of
Components
Parts
Li
st
Circuit
Diagram
Removal of the !Vetal Case
1024.1
1024.2
1024.3
1024.4
1024.5
1024.6
1024.7
1024
After removing
the
four threaded
re
tainers
at
the
back
of
the instrument,
it
is
possible to
slide
the
chassis
and
the
front ponel
out
of the
case.
Troub
le
Shooting
If
the
reason for a
fault
is
not an obvious one such as a de
ad
tv
be,
broken down resistor, blown or
disconnected
fuse
etc.,
then
first
test
the
voltages
of
all
the
tubes and compare them with the
voltages
shown in
the
circuit
diagram in order to
localize
the
defect.
Should this method of finding the fault prove unsuccessful, then
check
the
instrument
by
adopting
the method described in
the
adjustment procedure . When
the
trouble has
be
en found and
remedied,
the
vo
ltages
and
adjustments which
ar
e i
nfluenced
by
the remedy must
be
rechecked.
The
tolerances
stated
in
the
instructions
can
anly
be
used as a
guide
for
adjustment and
control,
but
any
deviations
must not be
corrected
without being sure
that
the
tolerances
of
the instruments used for making the
ad
justme
nt
are
so small
as
to
have
no
i
n-
fluence on
the
mea$urements .
The instructions in this
tv\anual
are
given purely as a
guide
to
the
service
of
equipment with minor faults . Some
faults,
as f .inst.
small
deviations
in
tolerances
require
for
their
correctio
n
special
control equipment
and
extensive
experience,
and in these cases
it
is necessary to
~nd
the
instrument to
the
factory .
~
Please
state
type
and
serial numb
er
of apparatus when spare parts
are
ordered.
Instruments necessary for
service
and
repair
Multimeter
(SO
~)
Frequency Analyzer Type 2107
(Frequency
counter
or a frequency standard and a
service
oscilloscope)
(Vacuum Tube Voltmeter Type 2409)
(Frequency
and
Distortion .v.easuring
Br
Jdge Type 1607)
1024-16
5
Question and Answer IconNeed help?

Do you have a question about the BRUEL & KJAER 1024 and is the answer not in the manual?

BRUEL & KJAER 1024 Specifications

General IconGeneral
BrandBRUEL & KJAER
Model1024
CategoryInverter
LanguageEnglish

Summary

Meter Circuit Adjustments

Mechanical Zero-point Calibration

Adjust for zero output with no power applied.

Meter Circuit Balance Adjustment

Adjust output level for specific deflection and check voltages.

Sensitivity Verification

Adjust output level for precise deflection and check sensitivity.

Meter Time Constant Check

Adjust output level for deflection and check meter response time.

Voltage Divider Calibration

Adjust output level for deflection and check voltage divider accuracy.

Output Amplifier Performance Checks

Frequency Response Verification

Adjust output level and vary frequency to check response.

Power Output Testing

Check power output capability and voltage with specified load.

Instability Check

Check amplifier stability by applying a condenser and observing oscillation.

Attenuator Performance

Adjust output level and check attenuator positions against a reference.

Distortion Measurement

Adjust output level and check distortion at various frequencies.

Noise and Hum Measurement

Measure noise and hum levels under specified conditions.

Output Transformer Check

Adjust output level and check output transformer performance.

Oscillator Calibration Procedures

Fixed Oscillator Adjustment

Adjust air trimmer for target frequency on the 123 kHz socket.

Variable Oscillator Calibration

Adjust air trimmer and iron core for specific frequencies.

3 kHz Filter Verification

Adjust filter components and check frequency response curve.

3 kHz Oscillator Frequency

Short-circuit and connect frequency counter to verify oscillator frequency.

Noise Generator Calibration

Connect oscilloscope and adjust output level for noise distribution check.

1000 Hz Reference Signal

Adjust oscillator at line frequency and set reference signal.

120 kHz Selective Amplifier

Adjust output level and filter iron cores for maximum deflection.

Balanced Modulator Check

Measure signal level after short-circuiting to ground.

Frequency Drift Monitoring

Adjust oscillator after warm-up and monitor drift over time.

Magnet Clutch Lubrication

Lubricate magnet slip-ring and capacitor-slipper with petroleum jelly.

Compressor Functionality Tests

Compressor Balance Adjustment

Adjust output level and check signal on anodes of V 14.

Frequency Response of Compressor

Adjust compressor voltage and vary frequency to check response.

Gain Reserve Measurement

Adjust output level with compressor input disconnected.

Compression Ratio Test

Adjust compressor voltage and check deflection change.

Component Layout Diagrams

Main Board Component Layout

Diagram showing component placement on the main printed circuit board.

Sub-board Component Layout

Diagram showing component placement on secondary printed circuit boards.

Attenuator Component Layout

Diagram showing component placement for the attenuator section.

Bandwidth Selector Layout

Diagram showing component placement for the bandwidth selector.

Meter Switch Component Layout

Diagram showing component placement for the meter switch.

Parts List

Capacitors and Resistors

List of capacitors and resistors with stock reference and circuit diagram reference.

Switches and Potentiometers

List of switches and potentiometers with stock reference and circuit diagram reference.

Rectifiers and Tubes

List of rectifiers and vacuum tubes with stock reference and circuit diagram reference.

Miscellaneous Components

List of miscellaneous parts including connectors, knobs, and transformers.

Circuit Diagram

Overall Circuit Schematic

Comprehensive circuit diagram showing all functional blocks and components.

Related product manuals