11
225B BALANCE POINT WORKSHEET
0.0
2.9
5.9
8.8
11.7
14.6
17.6
20.5
23.4
0
10
20
30
40
50
60
70
80
BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH
225BNA018
FX4DNF019
225BNA024
FX4DNF025
225BNA042
FX4DNF043
225BNA030
FX4DNF031
225BNA060
FX4DNF061
225BNA048
FX4DNF049
225BNA036
FX4DNF037
- 10 (-23) 0 (-17.78) 10 (-12.22) 20 (-6.67) 30 (-1.11) 40 (4.44) 50 (10) 60 (15.56) 70 (21.11) 80 (26.67)
OUTDOOR TEMPERATURE, ºF (ºC)
BASED ON INDOOR ENT. AIR AT 70 ºF (21.1)