TROUBLESHOOTING
For ease of service, the systems are equipped with diagnostic code
display LEDs on both the indoor and outdoor units. The outdoor
diagnostic display consists of two LEDs (Red and Green) on the
outdoor unit board and is limited to a few errors.
The indoor diagnostic display is a combination of flashing LEDs
on the display panel or the front of the unit. If possible, always
check the diagnostic codes displayed on the indoor unit first.
The diagnostic codes displayed on the indoor unit are listed in
Table 8.
INDOOR UNIT DIAGNOSTIC GUIDES
Table 8—Indoor Unit Diagnostic Guides
OPERATION LAMP TIMER LAMP DISPLAY LED STATUS
1 time
X E0 Indoor unit EEPROM error
2 times X E1 Communication malfunction between indoor and outdoor units
4 times X E3 Indoor fan speed has been out of control
5 times X E4 Indoor room temperature sensor T1 open circuit or short circuit
6 times X E5 Evaporator coil temperature sensor T2 open circuit or short circuit
7 times X EC Refrigerant leakage detection
8 times X EE Water-level alarm malfunction
1 time O F0 Current overload protection
2 times O F1 Open circuit or short circuit of outdoor ambient temperature sensor T4
3 times O F2 Open circuit or short circuit of condenser coil temperature sensor T3
4 times O F3 Open circuit or short circuit of Compressor discharge temperature sensor T5
5 times O F4 Outdoor unit EEPROM error
6 times O F5 Outdoor fan speed has been out of control
7 times O F6 T2B sensor error
8 times O F7 Lifting-panel communication error
9 times O F8 Lifting-panel malfunction
10 times O F9 Lifting-panel is not closed
1 time P0 IPM malfunction
2 times P1 Over voltage or over low voltage protection
3 times P2 High temperature protection of compressor top
4 times P3 Outdoor low temperature protection
5 times P4 Inverter compressor drive error
6 times P5 Mode conflict
7 times P6 Compressor low-pressure protection
8 times P7 Outdoor IGBT temperature sensor error
O (light) X (off) ☆ (flash)
For additional diagnostic information, refer to the Service Manual.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
E2016 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 08/16
Replaces: II-619RC-538PR-02
Catalog No. II619RC-03

Other manuals for Bryant 619REQ018CBMA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant 619REQ018CBMA and is the answer not in the manual?

Bryant 619REQ018CBMA Specifications

General IconGeneral
BrandBryant
Model619REQ018CBMA
CategoryAir Conditioner
LanguageEnglish

Related product manuals