28
A190170
Fig. 31 -- Dual-- Fuel Thermostat with Variable Furnace and
Single-- Speed Heat Pump
A190171
Fig. 32 -- Dual-- Fuel Thermostat with Variable Furnace and
Two--Speed Heat Pump
A190172
Fig. 33 -- Two-- Stage Thermostat with Variable Furnace and
Two-- Speed Air Conditioner
A190173
Fig. 34 -- Single-- Stage Thermostat with Variable Furnace
and Two--Speed Air Conditioner
NOTES FOR FIGURES 27 -- 34
1. Heat pump MUST have a high pressure switch for dual fuel applications.
2. Refer to outdoor equipment Installation Instructions for additional information and setup procedure.
3. If the heat pump date code is 1501E or earlier, select the “ZONE position on the two--speed heat pump control. Heat pumps having date codes 1601E and
later do not have or require a “ZONE” selection.
4. Outdoor Air Temperature Sensor must be attached in all dual fuel applications.
5. Dip switch No. 1 on Thermidistat should be set in OFF position for air conditioner installations. This is factory default.
6. Dip switch No. 1 on Thermidistat should be set in ON position for heat pump installations.
7. Dip switch No. 2 on Thermidistat should be set in OFF position for single-- speed compressor operation. This is factory default.
8. Dip switch No. 2 on Thermidistat should be set in ON position for two-- speed compressor operation.
9. Configuration Option No. 10 “Dual Fuel Selection” must be turned ON in all dual fuel applications.
10. NO connection should be made to the furnace HUM terminal when using a Thermidistat.
11. Optional connection: If wire is connected, dip switch SW1--2 on furnace control should be set in ON position to allow Thermidistat/Thermostat to control
furnace staging.
12. Optional connection: If wire is connected, ACRDJ jumper on furnace control should be removed to allow Thermidistat/Thermostat to control outdoor unit
staging.
13. Furnace must control its own high--stage heating operation via furnace control algorithm.
14. The RVS Sensing terminal “L” should not be connected. This is internally used to sense defrost operation.
15. DO NOT SELECT the FURNACE INTERFACE” or “BALANCE POINT” opti on on the two--speed heat pump control bo ard. This is controlle d internal ly
by the Thermidistat/Dual Fuel Thermostat.
16. Dip switch D on Dual Fuel Thermostat should be set in OFF position for single--speed compressor operation. This is factory default.
17. Dip switch D on Dual Fuel Thermostat should be set in ON position for two--speed compressor operation.