72
Table 21 (Continued) -- Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate
26,000 BTUH ONLY
650
43 1.7 43 1.8 42 1.5 42 1.6
7001 675 44 1.8
43 1.7 43 1.7 43 1.8
(2134) 700 44 1.7 44 1.8 44 1.8
43 1.7
725 44 1.6 44 1.7 44 1.7 44 1.8
750 44 1.5 44 1.5 44 1.6 44 1.6
8000 775 44 1.4 44 1.4 44 1.5 44 1.5
(2438) 800 44 1.3 44 1.4 44 1.4 44 1.4
825 44 1.2 44 1.3 44 1.3 44 1.4
625
43 1.7 43 1.8 43 1.8 42 1.6
8001 650 44 1.8
43 1.7 43 1.7 43 1.8
(2439) 675 44 1.7 44 1.8 44 1.8
43 1.6
700 44 1.6 44 1.6 44 1.7 44 1.7
725 44 1.5 44 1.5 44 1.6 44 1.6
9000 750 44 1.4 44 1.4 44 1.5 44 1.5
(2743) 775 44 1.3 44 1.3 44 1.4 44 1.4
9001 600
43 1.7 43 1.8 43 1.8 42 1.6
(2744) 625 44 1.8
43 1.6 43 1.7 43 1.7
650 44 1.7 44 1.7 44 1.8 44 1.8
675 44 1.6 44 1.6 44 1.7 44 1.7
10000 700 44 1.4 44 1.5 44 1.5 44 1.6
(3048) 725 44 1.3 44 1.4 44 1.4 44 1.5
* Orifice numbers shown in BOLD are factory-installed.
U.S.A. Only
to
U.S.A. Only
to
U.S.A. Only
to
ORIFICE SIZE* AND MANIFOLD PRESSURE (IN WC) FOR GAS INPUT RATE
TABULATED DATA BASED ON 13,000 BTUH PER BURNER, DERATED 2%/1000 FT (305M) ABOVE SEA LEVE
A150572
915SA