EasyManua.ls Logo

Bryant CK3B User Manual

Bryant CK3B
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Form No. PDS CK3B.24.2
Cased Horizontal
Furnace Coil
CK3B
Sizes A024 thru A060
This horizontal N-Coil is designed to provide the highest
standard of reliability and durability. The CK3B coil casing is
unpainted embossed galvanized steel. The cabinet is fully
insulated to minimize energy loss.
The CK3B is designed for application with horizontal furnaces.
The 2-directional airflow allows for either horizontal-right or
horizontal-left furnace fit-up. This coil is ideally suited for either
attic or crawl space installation.
Our advanced manufacturing methods give a better bond of the
fin and tube. Contaminants are not introduced into coil during
manufacturing. Galvanic action is minimized. The coils are
approved for air conditioning or heat pump application in the
horizontal configuration.
The CK3B coil includes a refrigerant control metering device for
improved serviceability over check valves and expansion
devices used in conventional coils. Sweat-type connections are
furnished for installation of the refrigerant tubes.
The coil is designed to provide improved condensate removal.
The robust condensate pan has brass inserts in the primary and
secondary drain connections and meets FHA requirements.
Question and Answer IconNeed help?

Do you have a question about the Bryant CK3B and is the answer not in the manual?

Bryant CK3B Specifications

General IconGeneral
BrandBryant
ModelCK3B
CategoryFurnace Accessories
LanguageEnglish

Summary

CK3B Cased Horizontal Furnace Coil Overview

Product Features and Benefits

Highlights reliability, durability, and energy efficiency of the CK3B coil with its insulated galvanized steel casing.

Installation and Airflow Design

Details 2-directional airflow for horizontal furnaces, suitable for attics or crawl spaces.

Refrigerant Control and Connections

Explains the refrigerant metering device and sweat-type connections for improved serviceability.

Condensate Management System

Describes the robust condensate pan with brass inserts meeting FHA requirements.

CK3B Model Number Nomenclature

Coil Type and Configuration Codes

Explains the meaning of 'C', 'K', '3', and '5' in the CK3B model number.

Finish and Airflow Designators

Defines 'B' for Embossed and 'X' for Max. Cap. in model designations.

Capacity and Size Designations

Clarifies the numerical codes (024-060) representing tonnages and capacities.

CK3B Unit Dimensions and Weights

Dimensional Diagram and Key Labels

Illustrates the physical dimensions of the CK3B coil with labeled components and measurements.

Detailed Dimensions and Shipping Weights by Model

Provides a table of specific measurements (A-E) and shipping weights for each CK3B model.

CK3B Cooling Capacity Data

Cooling Capacity Tables

Presents cooling capacities (TC, SHC) for various unit sizes, CFM, and temperatures.

Capacity Calculation Notes and Formulas

Explains notes on SHC, superheat, and provides formulas for leaving air conditions.

CK3B Performance Specifications

Coil Static Pressure Drop Data

Lists static pressure drops for wet and dry coil conditions across different airflow rates.

Bypass Factor and Correction Factor Calculations

Details bypass factor tables and the formula for calculating correction factors for SHC.

CK3B Horizontal Installation Types

Horizontal Left Installation Diagram

Illustrates the typical setup for a horizontal left airflow installation.

Horizontal Right Installation Diagram

Shows the typical configuration for a horizontal right airflow installation.

Bryant Service Training Programs

Packaged and Classroom Training

Information on available service training programs for unit familiarization, installation, and maintenance.

Requesting a Training Catalog

Provides contact information to obtain a free catalog for service training courses and schedules.