User’s Information Manual for the Operation and
Maintenance of Heat Recovery Ventilators
Fig. 1 — Controls
A00030
OPERATING YOUR HEAT RECOVERY VENTILATOR (HRV)
Your HRV is designed to operate as an integral part of your total heating and cooling system. With the exception of high capacity
models, which are available with standard controls only, all HRVs offer 3 control options (See Fig. 1.):
Basic Controls: Allow the user to manually set the unit to low- or high-fan speed as required to maximize comfort. Controls may
be unit mounted.
Standard Controls: Offer automatic dehumidistat control and the option to select low speed or intermittent fan during heating season.
Automatic Controls: In addition to the operational features found with standard controls, automatic controls feature a recircula-
tion mode. Not for use with forced-air HVAC systems.
Fan Speed Control
—Enables user to modulate fan speed from low to high.
Dehumidistat Control
—Allows the user to select the relative humidity level at which the unit would change fan speed to avoid
condensation problems while heating during the winter months.
TABLE 1 — HUMIDITY SETTINGS
Continuous Mode
—If the relative humidity inside the building is lower than selected, air exchange would occur with the outside
at low speed. If the relative humidity level inside the building is higher than selected, air exchange would occur outside at high
speed. This ensures continuous air exchange for constant air quality.
Intermittent Mode
—If the relative humidity inside the building is lower than selected, no air exchange would occur, and the sys-
tem would turn off. If the relative humidity inside the building is higher than selected, air exchange would occur with outside at
high speed. This ensures minimum air exchange level when the building is unoccupied to minimize operating cost.
Recirculation Mode
—If the relative humidity inside the building is lower than selected, indoor air would be circulated and filtered
at high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with outside at high speed.
This ensures continuous movement and filtration of air for maximum comfort.
OUTSIDE TEMPERATURE DOUBLE-PANE WINDOWS TRIPLE-PANE WINDOWS
°C °F (PERCENTAGE) (PERCENTAGE)
10 50 55 65
0324555
–10 14 35 45
–20 2430 40
–30 –22 25 35
OFF HIGHLOW
ARRET HAUTEBASSE
% D HUMIDITE RELATIVE HUMIDITY
20
25
30
40
50
60
70
80
OFF
ARRET
LOW
BASSE
INTERMITTENT
AIR EXCHANGE
ECHANGE D´AIR
´
ON
MARCHE
% HUM. RELATIVE HUM.
55%
45%
35%
30%
EXT. TEMP. EXT.
% D´HUMIDITE RELATIVE HUMIDITY
´
% HUM. RELATIVE HUM.
55%
45%
35%
30%
EXT. TEMP. EXT.
MODE
AIR EXCHANGE
ECHANGE D´AIR
´
20
25
30
40
50
60
70
80
10°C/50°F
0°C/32°F
–10°C/14°F
–20°C/–4 °F
´
´
10°C/50°F
0°C/32°F
–10°C/14°F
–20°C/–4 °F
Basic Control Standard Control Automatic Control
USER’S INFORMATION MANUAL
MODELS HRVBBLHU,
HRVBBSVU, AND HRVBBLVU
HEAT RECOVERY VENTILATOR

Other manuals for Bryant HRVBBSVU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant HRVBBSVU and is the answer not in the manual?

Bryant HRVBBSVU Specifications

General IconGeneral
BrandBryant
ModelHRVBBSVU
CategoryFan
LanguageEnglish

Related product manuals