Table 5 – Additional Subcooling Required -- 13 SEER Units
Indoor Unit
Subcooling Delta from Rating Plate Value
Outdoor Unit Tonnage
018 024 030 036 042 048 060
CAP**1814A** --- ---
CNPV*1814A** --- ---
CNPV*1917A** +5
FB4CNF018+TXV --- ---
FF1ENP(018/019) --- ---
FX4DNF019 +3
CAP**24**A** +3 +3
CNP**24**A** +3 +3
CSPH*2412A** +5 +5
FB4CNF024+TXV --- --- --- ---
FF1ENP(024/025) +5 +3
(FV4C/FE4A)NF002 +5 +3 +3
FX4DNF025 +5 +3
CAP**30**A** +3 --- ---
CNP**30**A** +3 +3
CNP**3117A** +5 +3
CSPH*3012A** +3 +3
FB4CNF030+TXV +3 --- ---
FF1ENP030 +3 --- ---
FF1ENP031 +3 --- ---
FX4DN(B,F)031 +5 +5
CAP**36**A** +5 +3
CNP**36**A** +3 --- ---
CNPV*3717A** +5 +3
CSPH*3612A** +5 +3
FB4CNF036+TXV --- --- --- ---
(FV4C/FE4A)N(B,F)003 +5 +5 +3 --- ---
FF1ENP036 +5 +3
FF1ENP037 +5 +3
FX4DN(B,F)037 +5 +5
CAP**42**A** +3 --- ---
CNP**4221A** +3 --- ---
CNPH*4321A** +3 +3
CNPV*4217A** +3 --- ---
CNPV*4324A** +3 +3
CSPH*4212A** +5 --- ---
FB4CNF042+TXV +5 --- ---
FX4DN(B,F)043 +5 --- ---
CAP**4817A** +5 +3
CAP**48(21,24)A** +3 --- ---
CNP**48**A** --- --- --- ---
CSPH*4812A** +3 --- ---
FB4CNF048+TXV --- --- --- ---
(FV4C/FE4A)N(B,F)005 +5 +5 +3 --- --- --- ---
FX4DN(B,F)049 +3 --- ---
CAP**60**A** +5 +3
CNP**6024A** +3 --- ---
CNPH*6124A** +5 +5
CNPV*6124A** +3 +3
CSPH*6012A** +5 +3
FB4CNF060 +5 --- ---
(FV4C/FE4A)NB006 +5 +5 +5 +3
FX4DN(B,F)061 +5 +3
213B / 215B

Other manuals for Bryant Legacy 215B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant Legacy 215B and is the answer not in the manual?

Bryant Legacy 215B Specifications

General IconGeneral
BrandBryant
ModelLegacy 215B
CategoryHeat Pump
LanguageEnglish

Related product manuals