Manual PRO v.2 47 / 53
Once the reading has stabilized and the chlorine measurement has been taken
with DPD1,
adjust the PPM value provided by the DPD1 measurement.
4.2- Warning message and alarms
In the event of abnormal operation, the SMART series equipment will display an
alarm message on the 4th line of the screen, together with an acoustic
warning. The alarms shutdown the equipment until the problem is solved.
Similarly, it will display a warning also in the 4th line, but without an acoustic
signal or shutting down the equipment. In this case, the equipment can
continue operating, although you are informed that corrective action should be
taken.
4.2.1- Warning messages
Message:
Causes:
Action required:
"LACK OF SALT"
Lack of salt in the water.
Add salt to the swimming pool.
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
The electrolysis cell is worn.
Replace the electrolysis cell with
a new one.
"EXCESS SALT"
Excess salt in the water.
No action required if excess is
not very significant.
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
"CLEANING"
The chlorinator is in the
self-cleaning process. The
process lasts 5 minutes
None.
"TEMPERATURE".
The ambient temperature is
>40º
Try and place the equipment in
another position where it is not
over 40º or perform forced
ventilation. Leave the
equipment to rest for a few
minutes.
Consult section number
4. Installation