22
DP12VL
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
Chuck falls off
spindle
Dirt, grease, or oil on the
tapered surface on the
spindle or in the chuck
Clean the tapered surface of both
the chuck and spindle with a
household detergent.
Motor will not run
Motor stalls
1) Defective or broken
switch
2) Defective or damaged
power cord
3) Open circuit, loose
connections, or burned .
out motor
4) Low voltage
5) Bad starting capacitor
6) Worn centrifugal switch
contacts
1) Short circuit in motor
2) Incorrect fuses or
circuit breakers
3) Overloaded circuit
4) Low voltage
1) Contact customer service
2) Replace with correct fuse or
circuit breaker for the circuit.
3) Turn off other machines and
retry.
4) Check the power line for the
proper voltage. Use another circuit
or have a qualified electrician
upgrade the service.
1) Contact customer service
2) Contact customer service
3) Contact customer service
4) Check the power line for the
proper voltage. Use another circuit
or have a qualified electrician
upgrade the service.
5) Contact customer service
6) Contact customer service
TROUBLESHOOTING