Introduction
The Ecomatic 2000
co
ntrol system is mainly
designed for single family and terraced houses.
The HS 2102 control panel is fitted with the
co
mplete safety-technical equi
pm
e
nt.
It can be
used for outdoor temperature dependent control
of
a low temperat
ur
e boiler with one-stage
burne
r,
a heat
in
g circuit without mixing v
al
ve and
f
or
domestic water heating.
You can adjust the angle of the visual
co
ntrol
panel during installation so that you can always
see the display irrespecti
ve
of how high you fix
the control panel itse
lf.
The operating rule is: first
"pr
ess"
th
en "turn
".
All functions and values to be set are shown in
the clear visual control pane
l.
"The
co
ntrol
speaks
yo
ur language".
Each function is assigned to a button.
Wh
en a
button is
pr
essed down, the va
lu
es can be
changed with the knob.
Th
e new value is
accepted when you release the button.
The
co
ntrol pan
el
is fitted wi
th
the following
fu
nctions:
- 1 channel
tim
e switch with weekly program
- automatic summer/winter changeover
- domestic water
pr
i
or
i
ty
switch
- domestic wat
er
heating
30
mi
nutes before
heating operation
- vacation program
- frost protection function
- 8 standard programs. You can also create your
own program when none
of
these standard
programs suits your requirements
- pump lag time of 3
mi
nutes for heating circuit
pump and storage tank loading pump
depending on operational conditions
- condensation protection
-
fl
ue gas test using technician button
- time and date are held for a ce
rt
ai
n period after
a power failure. All other settings are per-
manently stored.