3. Remove the plug from the Manifold Pressure Test Point and install a portable manometer. Check
for gas leak on the connection.
4. Turn ON the isolation gas valve, and open one burner and set at “High Flame” for Check the
pressure reading in the manometer. The manometer pressure reading should be according to
the pressure of the gas type indicated in the rating label and on the Gas Specification Table on
page 5 of this manual.
5. Once the burner operating pressure had been confirmed to be within the requirement, turn OFF
the burner and pilot, shut off the isolation gas valve, and remove the portable manometer from
the Manifold Pressure Test Point, and return the plug. Then, check for gas leak after returning
the plug.
6. Plug in the Piezo igniter, and return the front panel cover, and the control knobs.
7. Do not leave the premises until the functions of the following were fully checked and functional:
a. Lighting of the Pilot burners
b. Lighting of the Main burners
c. Setting of the “Low Flame”
d. Turning OFF of the Main burners
e. Turning OFF of the Pilot burners
Note that the procedure of the above processes is specified in the “Operation” section of this
manual.
8. The owner of the equipment must keep this manual along with the records of the purchase and
installation of the equipment for future reference.
9. It is essential that the operator/user was instructed for the correct procedure for lighting,
operation and shutdown of the equipment.