14
PROGRAMMING THE DISPENSER (Cont.)
Program Mode: Used to change or enter new set-up values.
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will
display “__PPP” to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use
the Increase (+) and Decrease (-) switch to adjust the values.
Tank Temperature Default = 180°F
Range = 120° - 190°F
Ready Temp = Tank Temp minus 10°F
P 1 1 8 0
LCD DISPLAY PROGRAM MODE DESCRIPTION
Left (Regular) Dispense Ratio Set Regular Coffee Ratio
Default = 38:1
Range = 25 Max / 50 Min
P 2 3 8
Right (Decaf) Dispense Ratio Set Decaf Coffee Ratio
Default = 38:1
Range = 25 Max / 50 Min
Cup Dispense Volume Set Cup Dispense Volume
Default = 0.0, Push & Hold
Range = 0.0 / 16.0 Oz.
P 4 0 0 0
Carafe Dispense Volume Set Carafe Dispense Volume
Default = 0.0, Disabled
Range = 0.0 / 64.0 Oz.
P 5 0 0 0
Left (Regular) Dispense Total Reset Total to Zero (00.0 Gal)
P 6 0 0 0
37935.1 052305
P 3 3 8