The BUNN
®
paper filter must be
centered in the funnel and the bed
of grounds leveled by gently shak-
ing.
The nut on the solenoid(s) must be
tight or it will vibrate during opera-
tion.
Plumbing lines should not be rest-
ing on the counter top.
(A) The brewer must be connected
to a cold water line.
(B) Water pressure to the brewer
must not exceed 90 psi(620 kPa).
Install a regulator if necessary to
lower the working pressure to ap-
proximately 50 psi (345 kPa).
Remove and clean lime off the
tank heater. See page 27
1. Funnel Loading
1. Solenoid(s)
2. Plumbing Lines
3. Water Supply
4. Tank Heater
Dry tea leaves remain in the funnel
Brewer is making unusal noises
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
10145 072600