TROUBLESHOOTING (cont.)
PROBLEM
Inconsistent beverage level in de-
canter (cont.)
Consistently high or low beverage
level in decanter.
Dripping from sprayhead
Beverage overflows decanter.
Weak beverage
PROBABLE CAUSE
3. Syphon System
1. Brew timer adjustment
1. Syphon System
2. Solenoid valve
1. Beverage left in decanter
2. Incorrect decanter size.
1. Type of paper filters
2. Coffee
3. Sprayhead
REMEDY
Water should flow freely from the
sprayhead for approximately
twenty seconds after the brew
solenoid has shut off and then
stop flowing abruptly. The brewer
must be level from side-to-side to
syphon properly.
Adjust the brew timer as required
to achieve the recommended 64
oz. for each brew cycle.
Water should flow freely from the
sprayhead for approximately
twenty seconds after the brew
solenoid has shut off and then
stop flowing abruptly. The brewer
must be level from side-to-side to
syphon properly.
Refer to
Service -
Solenoid valve
for testing procedures. See page
25.
The brew cycle should be started
only with an empty decanter un-
der the funnel.
Use only 64 oz. decanters.
BUNN
®
paper filters should be
used for proper extraction.
A sufficient quantity of fine or drip
grind coffee should be used for
proper extraction.
Bunn-O-Matic sprayhead
#01082.0000 should be used to
properly wet the bed of ground
coffee in the funnel.
10179 060100

Other manuals for Bunn VLPF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn VLPF and is the answer not in the manual?

Bunn VLPF Specifications

General IconGeneral
Voltage120V
Carafe TypeGlass
MaterialStainless Steel
ColorBlack
Brewing Capacity3.8 gallons per hour
TypePourover Coffee Brewer

Related product manuals