SERVICE (cont.)
LIQUID LEVEL CONTROL SYSTEM (cont.)
Removal and Replacement:
1. Remove all wires from the liquid level control
board terminals.
2. Remove the two #8-32 slotted-head screws hold-
ing the circuit board to the brewer hood.
3. Install the new circuit board to the hood, making
sure that the two lock-washers are in place below
the board and above the spacers.
4. Refer to FIG. 13 when reconnecting the wires.
WHI/BRN to Relay (Term. #2)
WHI/RED to Start Switch
WHI/RED to Relay(Term. #5)
WHI to Timer
WHI to Solenoid
PNK to Probe
FIG. 13 LIQUID LEVEL CONTROL
BOARD TERMINALS
P1985.70