Injector table (BGC60DW-BGC60DB)
G30 28-30mbar 12.0 kW 873 g/h
II2H3+ GB Class: 1
NG
G20 20
mbar
LPG
G30/G31
28-30/37 mbar
LARGE BURNER
DIA. of INJECTOR (1/100mm) 115 85
NOMINAL RATING (kW) 2,9 3
CONSUMPTION 276 l/h 218,1 g/h
MEDIUM BURNER
DIA. of INJECTOR (1/100mm) 97 65
NOMINAL RATING (kW) 1,75 1,75
CONSUMPTION 166.7 l/h 127,2 g/h
MEDIUM BURNER
DIA. of INJECTOR (1/100mm) 97 65
NOMINAL RATING (kW) 1,75 1,75
CONSUMPTION 166.7 l/h 127,2 g/h
SMALL BURNER
DIA. of INJECTOR (1/100mm) 72 50
NOMINAL RATING (kW) 1 1
CONSUMPTION 95.2 l/h 72,7 g/h
MAIN OVEN BURNER
DIA. of INJECTOR (1/100mm) 115 75
NOMINAL RATING (kW) 2,4 2,4
CONSUMPTION 228,6 l/h 174,5 g/h
GRILL BURNER
DIA. of INJECTOR (1/100mm) 110 69
NOMINAL RATING (kW) 2,2 2,1
CONSUMPTION 209,5 l/h 152,7 g/h