operating temperature H2S | -40° to +50°C (-40° to +122°F) |
---|---|
operating temperature CO | -30° to +50°C (-22° to +122°F) |
operating temperature O2 | -20° to +50°C (-4° to +122°F) |
operating temperature SO2 | -30° to +50°C (-22° to +122°F) |
operating humidity | 5% to 95% relative humidity (non-condensing) |
detection range H2S | 0 to 100 ppm |
---|---|
detection range CO | 0 to 300 ppm |
detection range O2 | 0 to 25% by volume |
detection range SO2 | 0 to 100 ppm |
audible alarm | ≈ 95 dB at 10 cm (3.9 in) |
alarm setpoints H2S low | 10 ppm |
alarm setpoints H2S high | 15 ppm |
alarm setpoints CO low | 35 ppm |
alarm setpoints CO high | 200 ppm |
alarm setpoints O2 low | 19.5% vol |
alarm setpoints O2 high | 23.5% vol |
alarm setpoints SO2 low | 5 ppm |
alarm setpoints SO2 high | 10 ppm |
battery type | Lithium, non-replaceable |
---|
sensor type | Electrochemical cells |
---|---|
display type | Liquid crystal display (LCD) |
instrument weight | 92 grams (3.2 ounces) |
---|---|
instrument dimensions | 41 x 50 x 87 millimeters (1.6 x 2.0 x 3.4 inches) |
Identifies key physical components of the BW Clip detector like LCD, alarms, pushbutton, and sensor.
Explains the meaning of various symbols displayed on the detector's LCD for different operational states and warnings.
Step-by-step guide for the initial activation and internal diagnostic testing of a new BW Clip detector.
Describes the detector's state when functioning normally, displaying gas type and remaining operating life.
Details how the detector displays remaining operating life in months, then days, and finally hours before expiry.
Explains the detector's state when its service life has ended, disabling safety functions.
Covers automatic internal tests, the diagnostic fail-safe sequence, and resulting detector deactivation.
Details low, high, and over/under-limit gas concentration alarms, including audible and visual cues.
Explains the automatic zero reminder for O₂ models and peak reading display.
Describes the non-compliance symbol and LED patterns for diagnostic failures, failed tests, or expiry warnings.
How to cycle through stored events like peak readings, alarms, and settings using the pushbutton.
Procedure for calibrating the sensor baseline, especially important for O₂ models.
Information on performing bump tests to verify sensor response and functionality.
Details the types of events logged by the detector and how to transfer them.
Enabling features like displaying gas readings during alarms or real-time clock via IntelliDoX.
Explains how to suspend a detector's operation for extended periods using a hibernation case or software.
Details about the operator guide, its scope, and copyright information.
Specifies detector service life based on usage and the measurement ranges for different gases.
Lists the default low and high alarm concentration setpoints for H₂S, CO, O₂, and SO₂ detectors.
Details the safety standards and certifications the BW Clip detector complies with.
Provides details on shelf life, weight, dimensions, operating conditions, and alarm types.
Outlines the product's limited warranty, exclusions, and limitations of liability.